Cabinet Smoke Exhaust Fan IP65 1,000 Pa for Kitchen Use

Adopting the method of motor cantilever installation and direct transmission, it greatly reduces the noise of the fan and improves the transmission efficiency of the motor. The protection level of the entire series of motors reaches IP65. It uses high-temperature coils and high-temperature ball bearings, which can effectively solve complex environmental problems such as high temperature and high humidity in kitchen fans.

  • Overview
  • Recommended Products

PCF Series High Voltage Low Noise Cabinet style Smoke Exhaust Fan

The PCF Series High Voltage Low Noise Cabinet style Smoke Exhaust Fan is an industrial-grade centrifugal unit built for continuous smoke exhaust service in commercial buildings and public spaces. It delivers up to 10,000 m³/h airflow at 1000 Pa maximum static pressure, across eight power variants from 0.75 kW to 5.5 kW. Motor cantilever installation and direct transmission reduce operational noise while improving motor transmission efficiency. Every motor carries an IP65 protection rating and uses high-temperature coils with high-temperature ball bearings — components chosen to handle the combined thermal and humidity demands of commercial kitchen ventilation and building smoke control systems.

PCF Series High Voltage Low Noise Cabinet style Smoke Exhaust Fan (1).png

Core Technical Specifications

Parameter Value / Range
Power Range 0.75 kW, 1.1 kW, 1.5 kW, 2.2 kW, 3 kW, 3.8 kW, 4 kW, 5.5 kW
Maximum Flow Rate 10,000 m³/h
Maximum Static Pressure 1000 Pa
Motor Protection Rating IP65
Drive Type Direct transmission, cantilever motor installation
Installation Type Cabinet style — ceiling or wall integration
Thermal Components High-temperature coils and high-temperature ball bearings
Construction All-metal


Key Features

IP65 Motor Protection for Moisture and Particulate Resistance

Every motor in the PCF Series carries an IP65 rating, providing full protection against dust ingress and low-pressure water. In commercial kitchen environments — where grease vapor, moisture from cleaning, and sustained elevated humidity are daily operating conditions — IP65 protection is a safety baseline, not an optional upgrade. A motor failure in a kitchen exhaust installation creates compliance exposure and operational downtime that compounds quickly in catering environments. The IP65 rating ensures the motor assembly stays sealed against the particulate and moisture loads that characterize its intended service conditions.

High-Temperature Coils and Ball Bearings for Thermal Durability

The PCF Series uses high-temperature coils and high-temperature ball bearings in every motor assembly. This component selection separates a genuine smoke exhaust fan from a general-purpose ventilation fan with similar airflow ratings. Standard fans are not rated for the sustained temperatures they face in an actual fire event or in continuous high-heat kitchen exhaust service. Using an unqualified product in a smoke exhaust zone creates a compliance gap that building inspections are designed to flag. The PCF Series addresses this through thermal components engineered for sustained performance under fire-condition temperatures and high-ambient heat.

Motor Cantilever Installation and Direct Transmission for Low Noise

Direct transmission with cantilever motor installation eliminates the belt-and-pulley path that generates mechanical noise in conventional fan configurations. Yes, the direct transmission interface is more precisely engineered than a belt drive — that is a real consideration. But if you are operating a hotel lobby, a shopping mall concourse, or a kitchen adjacent to dining areas, the noise reduction translates directly to a better acoustic environment and reduces the risk of noise-related complaints at building commissioning. The direct transmission path also improves motor transmission efficiency, delivering cleaner mechanical output and reducing component wear over extended service.

Compact Cabinet Form Factor for Space-Constrained Projects

The cabinet-style design integrates the motor within the fan structure, producing a compact unit with a small physical footprint. This is practically useful in the spaces where smoke exhaust fans are most needed: shopping mall ceiling voids, hotel service corridors, kitchen ceilings, and basement mechanical rooms where equipment space is constrained. The compact structure reduces installation coordination effort and is valuable in renovation projects where ceiling void depth is fixed by existing structure. Engineers gain more flexibility in coordinating mechanical, architectural, and structural design elements.

Application Scenarios

Commercial Kitchen and Catering Facility Smoke Exhaust

The PCF Series High Voltage Low Noise Cabinet style Smoke Exhaust Fan was developed with commercial kitchen conditions as the engineering baseline: sustained high temperatures from cooking equipment, oil-fume-laden air, moisture from steam and cleaning, and ceiling installations requiring high static pressure in limited space. The IP65 motor handles moisture and particulate exposure; the high-temperature coil and bearing assembly addresses continuous thermal loading; and the cabinet form factor allows ceiling void installation where axial fans would not fit. One selection note: specifying solely on floor area risks undersizing — the 1000 Pa maximum static pressure ensures the system performs in ducted runs with multiple bends and resistance.

Hotel Lobbies, Atriums, and Public Building Smoke Control

Smoke exhaust systems in hotel lobbies and public atriums must meet regulations governing exhaust volume relative to space volume and occupancy loading, typically verified by fire authority inspection before building occupation. The PCF Series' 10,000 m³/h maximum flow rate and 1000 Pa static pressure support multi-zone smoke control designs in large public spaces. The low-noise design is a meaningful factor in lobby applications, where occupied areas are adjacent to mechanical equipment and acoustic performance is a handover criterion. Confirm that the selected power variant matches the smoke control engineer's calculated exhaust volume for each zone.

PCF Series High Voltage Low Noise Cabinet style Smoke Exhaust Fan (2).jpgPCF Series High Voltage Low Noise Cabinet style Smoke Exhaust Fan (1).jpg

Differentiation Advantages

The PCF Series High Voltage Low Noise Cabinet style Smoke Exhaust Fan differentiates on compliance-critical engineering factors: IP65 motor protection against moisture and particulate; high-temperature coils and bearings for fire-condition durability; all-metal construction for long-service heat resistance; and direct transmission for low-noise operation in occupied buildings. For buyers comparing against lower-cost alternatives, the relevant metric is total installed cost plus compliance confidence. A fan that fails a commissioning inspection or requires additional acoustic enclosures introduces downstream costs that typically exceed the initial price difference.

For high-voltage infrastructure installations — large commercial buildings, industrial complexes, and facilities with high-voltage distribution — the PCF Series' high-voltage motor compatibility eliminates the step-down transformer installations required by standard-voltage products. This simplifies the electrical system architecture and reduces the number of components requiring inspection over the building's service life.