Ventilatores centrifugales ad altam pressionem 9-19 possunt amplitudine uti pro transferendo materiam, aera, et gases qui non sunt corrosivi, non se incendunt, et non continent substantias viscosas. Temperatura medii transmissi generaliter non excedit 80 °C, et pulvis et particulae duriores contentae non sunt maiores quam 150 mg/m³. Aptus pro ventilatione forzata ad altam tensionem in industrias ut fabricatio generalis et metallurgia, vitrum, ceramica, radio, galvanoplastica, et baterias, necnon pro transporto materialium in industrias transformationis ut frumentum, cibum pro animalibus, pulvis mineralis, et plasticum.
- Conspectus
- Producta commendata
9-19 Ventilatores Centrifugales Ad Alta Pressio: Expositio Technica
Cum systema ventilationis industrialis aerem contra magnam resistentiam ductuum impellere debet, optio idonei generis ventilatoris iudicium technicum valde necessarium est. Ventilatores centrifugales ad altam pressionem seriei 9-19 ad applicationes sunt constructi, in quibus exigentiae capitis pressionis quod alternativa axialia communia praestare possunt superant. Si installatio tua ductus longos, flexus multiplices, aut pressionem retro processus implicat, series 9-19 has difficultates directe solvit.
Producti Definitio
Ventilatores centrifugales ad altam pressionem 9-19 sunt constructi pro ventilatione forzata ad altam pressionem staticam et pro transportu materiarum in ambientes industrialis. Contra ventilatores axiales, qui aera parallelam ad axem movet, ventilatores centrifugales fluxum perpendicularem ad introitum reorient. Haec geometria impellit ut impeller aera continuo per viam laminae energiam addat, quare designes centrifugales pressionem producere possunt etiam dum resistentia systematis crescit — proprietatem quam ventilatores axiales in systematibus ductorum ad altam resistentiam replicare non possunt. Impeller centrifugalis torque motus in accelerationem fluxus radialis convertit, generans differentiales pressionis multo altiores quam unitates axiales comparabilis magnitudinis.
Medium quod transmittitur necesse est esse non-corrosivum, non-spicuum, et sine substantiis viscosis. Temperatura medii non debet superare 80°C, et pulvis aut particulae duræ debent manere ad vel infra 150 mg/m³. Hi parametri definient ambitum operationis; specificatio horum ventilatorum extra hunc ambitum requirit productum diversum.


Specificatiores Core de Performance
| Parametrum | Valor |
|---|---|
| Fluxus Aëris Maximus | 7 000 m³/h |
| Maxima Pressio Totalis | 9 200 Pa |
| Fluxus Aeris Typicus (per unitatem) | 824–1 284 m³/h |
| Pressio Typica (per unitatem) | 3 253–3 507 Pa |
| Voltius Motoris | 380V |
| Motoris Potentiae Campus | 0,75 kW – 30 kW |
| Limitis Temperaturae Medii | ≤ 80°C |
| Maxima Concentratio Particulorum | ≤ 150 mg/m³ |
Configuratio motoris 380V ventilatorum centrifugalium ad altam pressionem seriei 9-19 connectitur directe ad infrastructuram industrialem triphasicam standardem. Pro facilis quae iam operantur ad distributionem 380V, hoc eliminat impensas pro transformatoribus reductoribus quae alioquin accumulantur in installationibus multis unitatum.
Proprietates Claves
Spirae Motoris Omnino Cupreae
Motor usat windings de cuprum purum (100 %), non alternativis de aluminium. Alternativis de winding de aluminium sunt plus commun in unitatis cum pretio reducto, quia aluminium est leviore et minus pretiosum ad tractandum. Compensatio est resistentia electrica superior per sectionem unitatis, quae ducit ad amissiones energiae maiores ad currentem operativam. Pro applicationibus continuis quae plus quam 12 horas per diem operant, haec differentia accumulatur et potest affectare utrumque consumptum energiae et temperaturam operationis motoris. Cuprum praebet conductibilitatem thermicam meliorem et minores amissiones resistivas durante operatione continua sustentata. In praxi, plerique defectus thermici motorum non apparent in primis hebdomadibus — sed magis accumulantur per primam plenam stagionem operationis, praesertim ubi temperaturae ambientales in loco installationis non fuerunt confirmatae durante specificatio. Pro zonis ventilationis in fabricis metallurgicis vel pro inclosum malè ventilatis, verificare temperaturam ambientalem ante motoris commissionem.
Suctio et Flatio Binae Usus
The 9-19 high-pressure centrifugal fans support both negative-pressure suction and positive-pressure blowing modes. This dual-use capability allows the same unit to serve material intake conveying or pressure-side air supply depending on duct system integration, reducing the need to stock two separate fan types for multi-mode facilities.
Thickened Inlet and Outlet Flanges
Inlet and outlet flanges are built with additional wall thickness. In ducted installations subject to vibration or thermal cycling, flange seal integrity is a common long-term failure point. The reinforced flanges reduce seal degradation and mechanical fatigue in the connection zone — relevant in material conveying applications where pipelines impose mechanical stress on the fan connection points.
Lata Potentiae Ambitus
Serie covers range from 0.75 kW to 30 kW across twelve motor steps: 0.75, 1.1, 1.5, 2.2, 3, 3.8, 4, 5.5, 7.5, 15, 18.5, and 30 kW. This broad range allows procurement teams to source multiple size grades from single product family, simplifying vendor qualification and after-sales logistics across different process zones.
Scenaria Applicationum
Heavy Industry Forced Ventilation
Ventilatores centrifugales ad altam pressionem 9-19 sunt certificati pro ventilatione compulsoria in ambientes fabbricationis, metallurgiae, vitri, ceramicae, electroplating, et confectionis batteriarum. Hae applicationes postulant ventilationem cum pressione positiva vel negativa regula, cum onere thermalis, fumis chemicis, aut particulis minutissimis intra parametrum medium certificatum. Pressio statica usque ad 9 200 Pa praebet caput necessarium ad impellendum aerem per ductus longos vel systemata ventilationis plurium aedificiorum, ubi unitates inferioris certificati amittunt efficaciam cum resistentia systematis crescit. Si temperatio ambientis manet infra 80°C et concentratio particularum infra 150 mg/m³, hi ventilatores sunt apti directe ad hanc classem installationum ventilationis compulsoriae.
Translatio materiae: frumentum, cibus animalium, pulvis mineralis, et plastica
In systematibus pneumaticis transportandis frumentum, cibum animalium, pulverem mineralium, et granula plastica, ventilatores centrifugales altae pressionis seriei 9-19 funguntur ut fons pressionis qui materiam per tubos transportantes impellit. Haec applicatio idonea est ubi materia non est corrosiva, non est inflammabilis, et concentratio pulveris manet aequa aut infra 150 mg/m³. Ad frumenti transportandum, verificare concentrationes subtilis pulveris durante maximo fluxu est gradus qui in designo systematis perficiendus est, non differendus ad tempus post commissionem.
Remotio pulveris et exhaustio fumorum
Hiis ventilatores possunt machinam pro pulvere in officina removendo et pro fumis industrialibus evocandis impellere. In collectoribus pulveris, decrementum pressionis per filtrum initio parvum est, sed crescit dum media filtrans particulas recipit. Ventilator axiali, qui ad velocitatem constantem operatur, minorem fluxum aeris habebit, cum resistentia crescat. Curva characteristicus ventilatoris centrifugalis melius apta est ad fluxum constanter retinendum per hanc variabilem resistentiam; ideo designa centrifugalia in systematibus extractionis pulveris cum filtro onerato praefertur. In ambientes productionis ceramicae aut vitri, ubi extractio fumorum constans requiritur, haec characteristicus pressionis conservandae stabiliorem operationem systematis per totum intervallum maintenance praebet.
Indicium Selectionis
Fan centrifugalis pressionis altioris 9-19 sunt unitates gradus industrialis, cuius inscriptio qualitatis documentata: numerus serialis fabricae, codex inspectoris controlus qualitatis, dies productionis, et certificatio efficacitatis energiae. Pro emptoribus transmarinis, specificatio 380V directe compatibilis est cum distributione industriali triphasi standardi in plurimis mercatibus, et fabricatio subpeditur documentis partuum tracabilium.
Praerogativa pressionis designis centrifugalibus maxime significativa est ubi resistentia ductus alta est. Pro exhaustu brevi cum pressione retro minima, unitas axialis pressionis inferioris sufficere potest ad pretium unitatis inferius. Valor horum fanorum pressionis altioris exacte in applicationibus industrialibus et manutentionis materialium, quae pressionem exigunt — ambitus operativus pro quo constructi sunt.